Heat Pump Balance Point & Backup Heat Calculator

Find the thermal balance point where a heat pump's output equals the house heating load as outdoor temperature falls, using the design heat loss and the heat pump's capacity at 47 °F and 17 °F, plus the auxiliary heat needed at design temperature, the economic balance point versus gas or resistance heat, and hours below the balance point.

Design heat loss of the house
Outdoor design temperature (99%)
Indoor setpoint
Heat pump capacity at 47 °F
Heat pump capacity at 17 °F
COP at 47 °F
COP at 17 °F
Electricity price
Gas price (for economic balance point)
Furnace / backup efficiency
Loading calculator…

How it works

UA = design load ÷ (T_in − T_design); load(T) = UA × (T_in − T); capacity(T) linear between the 47 °F and 17 °F ratings; balance point where they are equal; aux = load − capacity at design; economic balance where COP × gas cost per BTU = electricity cost per BTU

A heat pump's output falls as it gets colder outside while the house's heat loss rises, so the two lines cross at the thermal balance point — typically 25–35 °F for a conventional unit sized for the cooling load — below which supplementary heat must make up the gap. Plotting the two lines from the design heat loss and the AHRI 47 °F and 17 °F capacity ratings shows how much auxiliary heat is needed at the design temperature and how many kilowatts of electric strip heat or what size furnace to specify. A separate economic balance point compares the cost per BTU of the heat pump, which worsens as its COP drops in the cold, with gas or another backup: in dual-fuel systems the thermostat switches to the furnace below that temperature even though the heat pump could still run.

Worked example

A house losing 48,000 BTU/h at 5 °F (UA 738 BTU/h·°F) with a 3-ton heat pump rated 36,000 BTU/h at 47 °F and 24,000 at 17 °F balances at about 30 °F; at the 5 °F design point it delivers 19,200 BTU/h against a 48,000 load, so 28,800 BTU/h (8.4 kW → 10 kW of strips) of backup is needed. At $0.16/kWh and $1.40/therm through a 92% furnace, gas becomes cheaper below roughly 35 °F.

Frequently asked questions

Is a lower balance point always better?

For heating, yes — less backup. But a heat pump sized to hit a very low balance point may be oversized for cooling and cycle inefficiently, unless it is a variable-capacity unit. Cold-climate models solve this by holding capacity to −5 °F or lower.

Why is my thermostat's balance point different?

Many thermostats use a fixed "aux lockout" or "compressor lockout" temperature set by the installer rather than a calculated balance point; setting the aux lockout near the calculated thermal balance point and the compressor lockout near the economic one is the usual dual-fuel strategy.

Related calculators

Standard HVAC field formulas (sensible heat equation, fan laws, ASHRAE 62.2 and blower-door conventions) at sea-level air density unless noted. Use manufacturer data, a Manual J/D/S load calculation and a licensed HVAC technician for design and commissioning decisions.