Rectifier Filter Capacitor Calculator (Ripple Voltage)

Size the smoothing capacitor after a bridge, centre-tap or half-wave rectifier from load current, mains frequency and allowed ripple, with peak and average DC voltage and voltage rating.

Transformer secondary voltage
Load current
Mains frequency
Rectifier
Allowed ripple (peak-to-peak)
Diode forward voltage
Loading calculator…

How it works

C = I ÷ (k × f × V_ripple) with k = 2 for full-wave, 1 for half-wave · V_peak = V_rms × √2 − diode drops (2 for a bridge) · V_dc(avg) ≈ V_peak − V_ripple ÷ 2 · ripple RMS ≈ V_ripple ÷ (2√3)

After rectification the reservoir capacitor charges to the peak voltage and then supplies the load alone until the next peak, discharging by ΔV = I × Δt ÷ C. With a full-wave rectifier the peaks come twice per mains cycle (100 or 120 Hz), so half the capacitance gives the same ripple as a half-wave circuit. The formula is a slightly conservative approximation that treats the discharge as lasting the whole period. Choose a capacitor with a voltage rating at least 25% above the peak and a ripple-current rating above the load current, and remember electrolytics are often −20%/+80% tolerance.

Worked example

A 12 V RMS transformer feeding a bridge rectifier on 50 Hz mains with a 1 A load and 1 V of allowed ripple: C = 1 ÷ (2 × 50 × 1) = 0.01 F = 10,000 µF. The peak DC voltage is 12 × 1.414 − 1.4 = 15.57 V, the average output is 15.07 V and the capacitor should be rated 25 V. Ripple RMS is about 0.289 V (1.92% ripple factor).

Sources: Wikipedia — Ripple (electrical): capacitor-input filter · Wikipedia — Rectifier (smoothing)

Frequently asked questions

How do I calculate the filter capacitor for a rectifier?

C = I ÷ (2 × f × V_ripple) for full-wave, or I ÷ (f × V_ripple) for half-wave. 1 A at 60 Hz with 1 V ripple needs 8,333 µF full-wave.

How much ripple is acceptable?

For a linear regulator after the capacitor, keep the ripple trough above the regulator's input requirement (output + dropout voltage). 5–10% of the DC voltage is a common starting point for unregulated supplies.

Why is the DC voltage higher than the transformer rating?

The capacitor charges to the peak of the sine wave, which is √2 = 1.414 times the RMS value, minus the diode drops. A 12 V transformer gives about 15.6 V after a bridge, and more at light load.

Can the capacitor be too big?

A larger capacitor reduces ripple but increases the inrush current at switch-on and the peak diode current, and the transformer runs hotter. Very large banks may need a soft-start or NTC inrush limiter.