InfyCalculator
💻

Solar Panel Array Sizing Calculator

Size a solar array from your daily energy use, local peak sun hours and panel wattage — the kW needed and the number of panels.

Daily energy use
Peak sun hours per day
Panel wattage
System efficiency (derate)
Loading calculator…

How it works

Array W = daily kWh × 1000 ÷ (sun hours × efficiency) · Panels = ⌈array W ÷ panel W⌉

Peak sun hours convert a whole day of sunlight into an equivalent number of hours at full 1000 W/m² intensity, so an array’s daily output is its wattage times sun hours. Working backwards from your daily kWh gives the wattage required, inflated by a system derate factor (~75–85%) that covers inverter loss, wiring, heat, dust and panel tolerance. Dividing by panel wattage and rounding up gives the panel count.

Worked example

For 20 kWh/day at 5 peak sun hours and 80% efficiency: 20 × 1000 ÷ (5 × 0.80) = 20,000 ÷ 4 = 5000 W (5 kW). With 400 W panels that is ⌈5000 ÷ 400⌉ = 13 panels, an installed 5.2 kW.

Frequently asked questions

What are peak sun hours?

Peak sun hours are the day’s total solar energy expressed as hours of full-strength (1000 W/m²) sunlight. A location averaging 5 kWh/m²/day has 5 peak sun hours, even though the sun is up longer. Look up your region’s figure from a solar irradiance map.

Why include a system efficiency factor?

Panels never deliver their nameplate wattage in the field — inverter conversion, wiring resistance, heat, soiling and manufacturer tolerance all take a cut. A derate of 75–85% turns the ideal figure into a realistic one, so the array is sized large enough.

Does this size the battery bank too?

No — this covers only generation to match daily use. Off-grid systems also need battery storage sized for the nights and cloudy days you want to ride through, plus extra panel capacity to recharge them.