Marine DC Wire Size Calculator (ABYC 3% / 10% Voltage Drop, Ampacity, Fuse Size)

Size a boat's 12 V or 24 V DC wiring the ABYC way: minimum AWG (and mm²) for a 3% drop on critical circuits or 10% on non-critical ones over the round-trip length, checked against the 105 °C ampacity table with engine-room and bundling derates, plus the fuse or breaker to protect the wire.

Load current
One-way length, source to load
Length units
System voltage
Allowable voltage drop
Wire runs through an engine space
Bundled with other current-carrying conductors
Loading calculator…

How it works

circular mils = 10.75 × I × round-trip length (ft) ÷ allowable drop (V) · allowable drop = 3% (critical) or 10% (non-critical) of system voltage · pick the larger of the drop size and the ampacity size (ABYC E-11, 105 °C, × 0.85 in engine spaces, × 0.7/0.6/0.5 bundled) · fuse ≤ derated ampacity of the wire

On a 12-volt boat a few volts lost in the wiring is a big share of the supply — a VHF or a bilge pump on undersized wire simply does not get its rated voltage — so marine practice sizes wire for voltage drop first and heat second. ABYC E-11 allows 3% drop on circuits that matter for safety and navigation and 10% on the rest, calculated on the full round trip, and then checks the wire can carry the current at the temperatures found in engine spaces and bundles. The fuse is chosen to protect that wire, not the device. This calculator does the same steps.

Worked example

A 20 A load 20 ft from the panel on a 12 V critical circuit: 40 ft round trip and a 0.36 V allowance need 10.75 × 20 × 40 ÷ 0.36 ≈ 23,900 circular mils — 6 AWG (13.3 mm²), even though 18 AWG could carry 20 A by heat. Actual drop with 6 AWG is 0.33 V (2.7%); the wire may be protected by anything up to 120 A, so a 25 A fuse near the source suits the load. Allowing 10% instead, the same run would take 10 AWG.

Frequently asked questions

Why round-trip length?

Current flows out through the positive and back through the negative, and both lose voltage. The formula uses the total conductor length; a 20 ft run is 40 ft of wire. On boats with a negative bus close to the load, measure each leg and add them.

Can I use automotive or household wire?

No. Marine wire is finely stranded tinned copper with oil-, moisture- and heat-resistant insulation; automotive wire corrodes green inside the insulation within a few seasons, and solid house wire cracks with vibration. Use UL 1426 / BC-5W2 boat cable.

Where does the fuse go?

Within 7 inches of the power source (battery, bus or panel) so the whole length of wire is protected — within 40 inches if the wire is in a sheath or conduit, and 72 inches for the main battery-to-switch cable. Battery-terminal fuses (MRBF/ANL) make this easy.

Related calculators

Boating figures are planning estimates based on published rules of thumb and standards (USCG, ABYC, manufacturer tables). Your boat's capacity plate, builder documentation and local regulations govern; conditions at sea vary. Wiring standards summarised from ABYC E-11; consult the current standard and a qualified marine electrician.