Solar Panel Tilt Angle Calculator
Find the best tilt angle for solar panels at your latitude — fixed year-round, adjusted twice a year or four times a year — plus which way to face and the noon sun height month by month.
How it works
Fixed all year: tilt = 0.76 × latitude + 3.1° (latitude 25°–50°), or 0.87 × latitude below 25° · twice a year: summer 0.93 × lat − 21°, winter 0.875 × lat + 19.2° · four seasons: summer 0.92 × lat − 24.3°, spring/autumn 0.98 × lat − 2.3°, winter 0.89 × lat + 24° · noon sun height = 90° − |latitude − declination|
The tilt that collects the most sunlight over a year is a little flatter than your latitude, because the long summer days carry more energy than the short winter ones. These rules are Charles Landau’s least-squares fits to clear-sky insolation for latitudes 25° to 50°; adjusting the angle twice or four times a year adds a few percent more energy. Point the panels toward the equator — true south in the northern hemisphere, true north in the southern — and use magnetic declination to convert to a compass bearing. The monthly table shows the tilt that would face the noon sun directly on the 21st of each month.
Worked example
At latitude 40° N (Madrid, Philadelphia, Beijing) the best fixed tilt is 0.76 × 40 + 3.1 = 33.5°, facing true south. Adjusting twice a year, use 0.93 × 40 − 21 = 16.2° in summer and 0.875 × 40 + 19.2 = 54.2° in winter; with four adjustments, 12.5° in summer, 36.9° in spring and autumn and 59.6° in winter. The noon sun reaches 73.4° at the summer solstice, 50° at the equinoxes and 26.6° at the winter solstice.
Sources: Charles R. Landau — Optimum tilt of solar panels · NREL — Solar position and tilt (PVWatts documentation)
Frequently asked questions
Should solar panels be tilted at the same angle as my latitude?
Latitude is a good rule of thumb, but slightly flatter is better for year-round output: about 0.76 × latitude + 3.1° between 25° and 50°. At 40° that is 33.5° instead of 40°.
How much do I gain by adjusting the tilt seasonally?
Adjusting twice a year typically adds about 4–5% of annual energy over a fixed tilt, and four times a year a little more. Most rooftop systems stay fixed because the gain rarely pays for the extra hardware and work.
Which direction should solar panels face?
Toward the equator: true south in the northern hemisphere and true north in the southern hemisphere. East- or west-facing roofs still produce roughly 80–90% as much, with the peak shifted to morning or afternoon.
What tilt is best for winter or off-grid systems?
If you need the most energy in winter — for example a cabin or an off-grid battery system — tilt steeper, around latitude + 15° to 20°, so the panels face the low winter sun and shed snow.
Does a flat roof need tilted panels?
A tilt of at least 10° to 15° helps rain wash off dust. Near the equator, panels can lie almost flat, but a few degrees of tilt still help with cleaning.