Water Heater Size Calculator: Tank Gallons, First-Hour Rating or Tankless GPM

Find the right water heater size: the tank size and first-hour rating for an electric, gas or heat pump water heater from your household size or your peak-hour hot water use (DOE worksheet), or the flow rate, temperature rise and Btu/h or kW for a tankless unit.

Size a
Household size
Usage level
Showers in the busiest hour
Shaves
Hand dishwashing or food prep
Dishwasher loads
Top-loading washer loads (hot or warm)
Front-loading (HE) washer loads
Tank type
Showers running at once
Sink faucets running at once
Dishwasher running
Clothes washer filling with hot water
Shower head flow
Tankless type
Incoming cold water temperature
Hot water temperature
Loading calculator…

How it works

peak-hour demand = people × gal per person, or Σ uses × gal per use (DOE) · needed first-hour rating ≥ peak-hour demand · typical first-hour rating ≈ a × tank gal + b × 67 ÷ rise (electric 0.7, 28 · gas 0.7, 40 · heat pump 0.7, 30) · tankless: Btu/h = gpm × 500 × rise (°F), kW = Btu/h ÷ 3,412

A storage water heater is sized to your busiest hour, not to the day’s total. The US Department of Energy method adds up the hot water used in that hour (about 20 gal per shower, 2 per shave, 3 for hand dishwashing, 7 for a dishwasher, 25 for a top-loading or 15 for a front-loading washer) and asks for a first-hour rating at least that large. The first-hour rating, printed on the EnergyGuide label, is how much hot water a full tank delivers in one hour while it reheats, so it depends on the burner or element as well as the tank: a 40-gallon gas tank often beats a 50-gallon electric one. The quick mode multiplies the household by 10, 12 or 15 gal per person in the busiest hour. The calculator then estimates the first-hour rating of standard tank sizes for electric (4.5 kW), gas (about 40,000 Btu/h) and heat pump water heaters, scales the recovery to your temperature rise, picks the smallest tank that meets the demand and never goes below the common retailer rule of thumb for the household size. For a tankless heater the size is a flow rate: add the gallons per minute of everything that runs at once and multiply by 500 and the temperature rise to get the heat output in Btu per hour. Use the coldest incoming water of the year; DOE suggests 50 °F if you do not know it.

Worked example

A family of 4 with average use (12 gal per person in the busiest hour) needs 4 × 12 = 48 gal, so the heater’s first-hour rating should be at least 48 gal/hr. With 50 °F water heated to 120 °F (a 70 °F rise), a 4.5 kW electric tank delivers about 0.7 × tank + 26.8 gal/hr: a 40-gallon tank (≈ 55 gal/hr) already meets the demand, but the rule of thumb for 4 people is 50 gallons, so the recommendation is a 50-gallon (189 L) tank with an estimated first-hour rating of about 62 gal/hr. For a tankless gas heater running one 2.5 gpm shower and one 0.75 gpm faucet at the same rise: 3.25 gpm × 500 × 70 = 113,750 Btu/h of output, or about 119,737 Btu/h of gas input for a 95% condensing unit.

Sources: US DOE Energy Saver: Sizing a new water heater · ENERGY STAR residential water heaters key product criteria (first-hour rating, UEF) · Lowe’s water heater buying guide (capacity by household size) · Rheem Professional Classic electric water heater spec sheet (first-hour rating and recovery, 4.5 kW)

Frequently asked questions

What size water heater do I need for a family of 4?

Usually a 50-gallon electric or heat pump tank or a 40-gallon gas tank. The real test is the first-hour rating: it should be at least your busiest hour’s use, often 50–70 gallons for four people when two or three showers happen back to back.

Should I size by tank size or first-hour rating?

By first-hour rating. It is the hot water you actually get in a busy hour, including what the heater makes while you draw it down, and it is printed on the yellow EnergyGuide label. Two 50-gallon tanks with different burners or elements can have very different ratings.

How do I size a tankless water heater?

Add the flow of every fixture you will run at the same time (for example a 2.5 gpm shower and a 0.75 gpm faucet = 3.25 gpm) and find the temperature rise from your coldest incoming water to the set temperature. The unit must deliver that flow at that rise; the heat needed is gpm × 500 × rise in Btu per hour.

Is a bigger tank always better?

No. An oversized tank keeps more water hot around the clock, wasting standby energy, and costs more to buy and install. Choose the smallest tank whose first-hour rating covers your busiest hour.

What temperature should my water heater be set to?

About 120 °F (49 °C) for most homes. It saves energy and lowers the scalding risk. Some dishwashers without their own heater need 140 °F, which calls for a mixing valve at the taps.

Why does incoming water temperature matter?

The heater has to raise the water from the inlet temperature to the set point. Winter water at 40 °F needs an 80 °F rise to reach 120 °F instead of 70 °F, which cuts a tankless heater’s flow by about an eighth and slows a tank’s recovery.

Related calculators

Estimate for planning. Add a waste margin and confirm with your supplier and local codes.