Well Drawdown Calculator: Theis and Cooper–Jacob Cone of Depression
Predict drawdown around a pumping well with the full Theis solution and the Cooper–Jacob approximation from pumping rate, transmissivity, storativity, distance and time, with unit choices, the unconfined-aquifer correction, well efficiency, interference with a neighbouring well, radius of influence, specific capacity and drawdown-versus-distance and drawdown-versus-time tables and charts.
How it works
s = Q ÷ (4πT) × W(u), u = r²S ÷ (4Tt), W(u) = −0.5772 − ln u + u − u²/(2·2!) + u³/(3·3!) − … · for u < 0.01: s ≈ 2.303Q ÷ (4πT) × log₁₀(2.25Tt ÷ r²S) · R = √(2.25Tt ÷ S) · unconfined: s′ = b − √(b² − 2b·s) · superposition: s_total = Σ s from each well
When a well pumps a confined aquifer, water is released from storage as the pressure drops, and a cone of depression deepens and spreads with time. Theis (1935) solved the flow equation by analogy with heat conduction. Drawdown depends on the pumping rate, the aquifer’s transmissivity (how easily it carries water sideways) and its storativity (how much water it releases per metre of head drop), through the exponential-integral "well function" W(u). This calculator evaluates W(u) accurately for any u, using the series for small u and a rational approximation (Abramowitz & Stegun 5.1.56) for large u, so drawdown far from the well and at short times is also correct. Cooper and Jacob noticed that for small u (long times or short distances) the series reduces to a logarithm. That is why drawdown plotted against log time is a straight line, and why every tenfold increase in pumping time adds the same drawdown, Δs = 2.303Q/(4πT). The approximation is shown next to the Theis value with its validity (u < 0.01 is the strict rule; up to 0.05 is often accepted). The radius of influence is where the Cooper–Jacob line reaches zero drawdown; it grows with the square root of time. Because the equations are linear, the cones of several wells simply add up (superposition): enter the neighbour’s pumping rate to see the combined drawdown. For a water-table (unconfined) aquifer, use specific yield as S and choose Unconfined. The Jacob correction converts the Theis result to the larger real drawdown as long as it stays under about a quarter of the saturated thickness. Real pumping wells also have well losses in the screen and gravel pack; a well efficiency below 100% adds them to the drawdown inside the well.
Worked example
With the defaults: Q = 1,200 m³/day, T = 250 m²/day, S = 0.0003, at the well face r = 0.15 m after 30 days. u = 0.15² × 0.0003 ÷ (4 × 250 × 30) = 2.25 × 10⁻¹⁰ and W(u) = 21.64, so s = 1,200 ÷ (4π × 250) × 21.64 = 8.26 m (27.1 ft). Cooper–Jacob gives 0.880 × log₁₀(2.5 × 10⁹) = 8.27 m, almost the same because u is tiny. The radius of influence is √(2.25 × 250 × 30 ÷ 0.0003) = 7,500 m. A neighbour 300 m away sees 2.46 m of extra drawdown after 30 days (3.41 m after a year), and each tenfold increase in time adds 0.88 m. Specific capacity is 1,200 ÷ 8.26 = 145.2 m³/day per metre (8.12 gpm per ft).
Sources: Heath (1983), Basic Ground-Water Hydrology, USGS Water-Supply Paper 2220 · Aquifer test: Theis solution and well function — Wikipedia
Frequently asked questions
What is the difference between Theis and Cooper–Jacob?
Theis is the exact solution for an ideal confined aquifer and uses the well function W(u). Cooper–Jacob keeps only the first two terms of W(u), giving a simple logarithm that is accurate when u is small (long pumping times or points close to the well).
When is the Cooper–Jacob approximation valid?
When u = r²S/(4Tt) is below about 0.01, where the error is under 1%. Many hydrogeologists accept u < 0.05 for practical work. Far from the well or early in a test, use Theis.
Can I use this for an unconfined (water-table) aquifer?
Approximately, if drawdown is small compared with the saturated thickness (under about 25%). Use specific yield for S, choose Unconfined and enter the saturated thickness to apply the Jacob correction. Large drawdowns and early-time delayed yield need the Neuman solution.
Why is the drawdown in the well itself larger than predicted?
Well loss: turbulent flow through the screen and gravel pack adds a term roughly proportional to Q² that the aquifer equations do not include. Step-drawdown tests separate the two; enter a well efficiency to include it.
How far does a pumping well affect the water level?
In an ideal infinite aquifer the cone keeps spreading as √t, so the radius of influence after 30 days at T = 250 m²/day and S = 0.0003 is about 7.5 km. In practice rivers, lakes or leakage stop it growing, and the drawdown far out is small.
Related calculators
Textbook hydrogeology equations (Darcy, Theis / Cooper–Jacob, Thiem) with idealised assumptions: homogeneous, isotropic aquifer of infinite extent, fully penetrating well, laminar flow. Field values of K, T and S vary by orders of magnitude; use site pump-test data and a qualified hydrogeologist for well design, dewatering or contaminant-transport decisions.